Description
Nội dung bài viết
Toggle1 Introduction
The monitor is applicable for clinical monitoring in operating room, postoperative observation room, ICU/CCU ward, emergency room, etc. of adult, pediatric and neonate. The patient’s vital parameters (ECG (including ST-segment measurement and arrhythmia analysis), RESP, SpO2,PR, NIBP, TEMP, IBP and CO2, etc.) can be monitored. Monitored information can be displayed, reviewed, printed and stored..
2 Function
- 13.3″ high-definition touch screen design, easy and convenient to operate, elegant and concise in appearance.
- Independent physiological and technical alarm function, convenient for medical staff to quickly know patient’s condition.
- Luminous “ON / OFF” button design, convenient to operate at night.
- Modular design: the modules can be configured and combined flexibly and conveniently, expanded and upgraded at any time, meets the monitoring requirements of different departments on different parameters.
- Support dynamic hot-plugging parameter module: no need to restart the device, plug-and-play, change the monitoring parameters at any time as clinical requirements.
- Adopt high-performance processor, stable, reliable and fast to process information.
- Patient information can be rapidly entered, patient type (adult / neonate / pediatric) can be quickly switched, meets the requirements of different departments.
- Abundant analysis functions: 23 arrhythmia, full-lead ST-segment and pacing analysis; multiple calculation functions (such as calculation of drug concentration, titration table, hemodynamics, ventilation, oxygenation, renal function, etc.).
- With the functions of waveform freezing, holographic waveform storage and review.
- Automatic data storage in case of power failure; optional built-in memory card, achieves large-capacity data storage.
- With HDMI expansion interface, the display screen can be connected according to clinical requirements.
- Built-in large-capacity detachable lithium battery, ensures uninterrupted monitoring.
- Fanless design, ensures no noise and low power consumption during working.
- 3-channel built-in recorder used to print real-time waveform is optional.
- Connect to Central Monitoring System developed by our company by WiFi / Wired, convenient to transmit patient’s real-time data.
- Standby mode, be applied to ICU, avoids affecting patient’s rest, one-button switching, reduces the workload of medical staff.
3
Performance
- ECG
- Lead type:
3-lead: I, II, III
5-lead: I, II, III, aVR, aVL, aVF, V
12-lead: I, II, III, aVR, aVL, aVF, V1,V2,V3,V4,V5,V6
- Gain: 5mm/mV, 5.0 mm/mV, 10 mm/mV, 20 mm/mV, 40 mm/mV
- Scan speed: 5 mm/s, 25 mm/s, 50 mm/s
- HR
Measurement and alarm range:
Adult: 15 ~ 300 bpm
Pediatric/neonate: 15 ~ 350 bpm
Resolution: 1 bpm
Accuracy: ± 1 % or ± 1 bpm, whichever is greater
- ST-segment detection
Measurement and alarm range: – 2.0 mV ~ + 2.0 mV
Accuracy: – 0.8 mV ~ + 0.8 mV: ± 0.04 mV or ± 10 %, whichever is greater
Other range: unspecified
- Arrhythmia analysis: 23 kinds
- Pacemaker: yes
- RESP
- Measurement mode: R-F(RA-LL) impedance
- Respiration rate:
Measurement range:
Adult: 0 rpm ~ 120 rpm
Pediatric/neonate: 0 rpm ~ 150 rpm
Resolution: 1 rpm
Accuracy: 7 ~ 150 rpm, ± 2 rpm or ± 2 %, whichever is greater;
0 ~ 6 rpm, unspecified
- Apnea alarm:10 ~ 120 s, not alarm
- Scan speed: 25 mm/s, 12.5 mm/s, 25 mm/s, 50mm/s
- NIBP
- Measurement mode: Oscillometry
- Working mode: Manual/AUTO/Continuous
- Measurement interval in AUTO mode: 1min, 2 min, 5 min, 3 min, 5 min, 10 min, 15 min, 20 min, 30 min, 1 h, 1.5 h, 2 h, 3 h, 4 h, 8 h
- Measurementperiod in Continuous mode: 5 minutes
- Measurement and alarm range: 10~ 270 mmHg
- Resolution: 1mmHg
- Cuff pressure accuracy:± 3 mmHg
- Measurement accuracy:
Maximal mean deviation: ± 5 mmHg
Maximal standard deviation: 8 mmHg
- Over-pressure protection:
Adult mode: 297 ± 3 mmHg
Pediatric mode: 240 ± 3 mmHg
Neonatal mode: 147 ± 3 mmHg
- CONTEC SpO2
- Measurement range: 0% ~ 100 %
- Resolution: 1%
- Accuracy: 70% ~ 100 %, ± 2 %;
0 % ~ 69 %, unspecified
- PR
Measurement and alarm range: 25 ~ 250 bpm
Accuracy: ± 2 bpm or ± 2 %, whichever is greater
- NellcorSpO2
- Measurement range: 1% ~ 100 %
- Measurement accuracy: 70% ~ 100 %: ± 2 % (adult / pediatric)
70 % ~ 100 %: ± 3 % (neonate)
0 % ~ 69 %: unspecified
- NellcorPR
Measurement range: 20 ~ 300 bpm;
Measurement accuracy: 20 ~ 250 bpm, ±3 bpm;
251 ~ 300 bpm: unspecified;
Upper limit of alarm: upper limit – 2 ~ 300 bpm;
Lower limit of alarm: 20 bpm ~ lower limit + 2 bpm
- MasimoSpO2
- Measurement range: 1% ~ 100 %
- Measurement accuracy:
70 % ~ 100 %: ± 2 % (adult / pediatric, under conditions of no motion), ± 3 % (under conditions of motion)
70 % ~ 100 %: ± 3 % (neonate, under conditions of no motion)
1 % ~ 69 %: unspecified
- MasimoPR
Measurement range: 25 ~ 240 bpm
Measurement accuracy: ± 3 bpm (under conditions of no motion), ± 5 bpm (under conditions of motion)
Upper limit of alarm: upper limit – 2 ~ 240 bpm
Lower limit of alarm: 25bpm ~ lower limit + 2 bpm
- TEMP
- Channel: dual-channel
- Measurement range: 0~ 50 ℃
- Resolution: 1℃
- Accuracy: ±1 ℃
- CO2
- Measurement mode: mainstream or sidestream
- CO2measurement range: 0 ~ 150 mmHg
- CO2resolution: 1 mmHg: 0 ~ 69 mmHg
0.25 mmHg: 70 ~ 150 mmHg
- Accuracy:
0 ~ 40 mmHg: ± 2 mmHg
41 ~ 70 mmHg: ± 5 %
71 ~ 100 mmHg: ± 8 %
101 ~ 150 mmHg: ± 10 %
- AwRRmeasurement range:
Sidestream: 2 ~ 120 rpm
Mainstream: 2 ~ 150 rpm
- AwRRaccuracy: ± 1 rpm
- Apnea alarm:yes
- IBP
- Channel: 4-channel
- Label: ART, PA,CVP, RAP, LAP, ICP, P1, P2
- Measurement and alarm range: -50~ 300 mmHg
- Resolution: 1 mmHg
- Accuracy: ±2 % or 1 mmHg, whichever is greater
- Power supply: 100~ 240 V ~ 50/60 Hz
- Safety class: class I, defibrillation-proof type CF applied part
- Waterproof degree: IPX2
THÔNG TIN NHÀ NHẬP KHẨU VÀ PHÂN PHỐI MÁY THEO DÕI BỆNH NHÂN TS13
Thông tin liên hệ Công ty TNHH Thương Mại Kỹ Thuật Quốc Tế VNS
Tư vấn kỹ thuật và báo giá :
0969 666 603 (Mr. Nam: Sales Manager)
HotLine: 028 2200 3333
Email : Info@vnsgroup.com.vn | HoangNam.Agpps@gmail.com
Địa Chỉ VP: 453B Đường Chiến Lược, Khu Phố 6, Phường Tân Tạo, Quận Bình Tân, TP.HCM
Địa Chỉ Kho Hàng: C2/34/E3 Đường Bầu Gốc, Ấp 3, Xã Tân Kiên, Huyện Bình Chánh, TP.HCM
Website : www.vnsgroup.com.vn | www.khinen.com.vn | www.vnsgroup.net
Quý khách hàng vui lòng liên hệ để được tư vấn những Option cao cấp hơn giúp tăng tuổi thọ của sản phẩm cũng như giảm thời gian bảo trì lắp đặt.
TẠI SAO NÊN MUA SẢN PHẨM MÁY THEO DÕI BỆNH NHÂN CONTEC TS13 TẠI VNS GROUP
✅ Luôn hỗ trợ tư vấn miễn phí cho khách hàng như;
✅ Hỗ trợ tham quan khảo sát thiết bị tận nơi cho khách hàng.
✅ Cung cấp giá cả hợp lý cho khách hàng khi mua sản phẩm của công ty.
✅ VNS Group là nhà phân phối chính thức của Contec Medical tại Việt Nam.
✅ Bảo hành 1 năm cho các sản phẩm Máy Đo Chức Năng Hô Hấp và Máy Tạo Oxy theo tiêu chuẩn nhà sản xuất
✅ Cung cấp những giải pháp tối ưu và tốt nhất cho khách hàng.
✅ Giải quyết nhanh chóng đơn đặt hàng khi có yêu cầu đặt hàng.
Quý khách có thể kham khảo một số sản phẩm khác của công ty TẠI ĐÂY