Pediatric Fingertip Pulse Oximeter CMS-50QB Contec
The Pediatric Fingertip Pulse Oximeter CMS-50QB Contec is designed from the ground up with children in mind. Our Pediatric Fingertip Pulse Oximeter CMS-50QB Contec oximeters are specially designed to detect both the pulse rate and blood oxygen saturation level (SPO2).
The Pediatric Fingertip Pulse Oximeter CMS-50QB Contec is recommended for use on children ages 2 to 13, with a minimum body weight of 35 lbs, or 16 kg. The bright LCD display allows for easy viewing with high contrast. The sensor is calibrated to the thinner skin surface of children, whose skin could be as little as 0.3 inches (8mm). The bright LCD display allows for easy viewing with high contrast.
Features of Pediatric Fingertip Pulse Oximeter CMS-50QB Contec
- Comes with a built-in heartbeat tracker, first of its kind.
- This auditory blip helps keep track of the heart as its beating without having to look at the display visually.
- An auditory alarm is also included that would detect when the heartrate or SpO2 exceeds a preset specification.
- Easy to operate, low power consumption, pulse bar and pulse graph display, Spo2 value display, low voltage indicator and real time data can be transmitted to computer for analysis.
- The product is suitable for being used in family, hospital, oxygen bar, community healthcare, physical care in sports (It can be used before or after doing sports, and it is not recommended to use the device during the process of having sport) and etc.
Specification of Pediatric Fingertip Pulse Oximeter CMS-50QB Contec
- Measurement of SpO2
- Measuring range: 0%~99%
- Accuracy: When the SpO2 measuring range is 70%~99%,the permission of absolute error is ±2%; Below 70% unspecified
- Measuring range:30bpm~250bpm
- Accuracy: ±2 bpm or ±2% (select larger)
- Power supply requirement 3.6 V DC ~ 4.2V DC Rechargeable Battery
- Resolution SpO2 : 1%, Pulse rate: 1bpm
- Measurement Performance in Weak Filling Condition: SpO2 and pulse rate can be shown correctly when pulse-filling ratio is 0.4%. SpO2 error is ±4%, pulse rate error is ±2 bpm or ±2%.
- Resistance to surrounding light. The deviation between the value measured in the condition of man-made light or indoor natural light and that of darkroom is less than ±1%.
THÔNG TIN NHÀ NHẬP KHẨU VÀ PHÂN PHỐI MÁY ĐO NỒNG ĐỘ OXY SPO2 CMS50QB
Thông tin liên hệ Công ty TNHH Thương Mại Kỹ Thuật Quốc Tế VNS
Tư vấn kỹ thuật và báo giá :
0969 666 603 (Mr. Nam: Sales Manager)
HotLine: 028 2200 3333
Email : Info@vnsgroup.com.vn | HoangNam.Agpps@gmail.com
Địa Chỉ VP: 453B Đường Chiến Lược, Khu Phố 6, Phường Tân Tạo, Quận Bình Tân, TP.HCM
Địa Chỉ Kho Hàng: C2/34/E3 Đường Bầu Gốc, Ấp 3, Xã Tân Kiên, Huyện Bình Chánh, TP.HCM
Website : www.vnsgroup.com.vn | www.khinen.com.vn | www.vnsgroup.net
Quý khách hàng vui lòng liên hệ để được tư vấn những Option cao cấp hơn giúp tăng tuổi thọ của máy đo nồng độ oxy trong máu cũng như giảm thời gian bảo trì lắp đặt.
TẠI SAO NÊN MUA SẢN PHẨM MÁY ĐO NỒNG ĐỘ OXY SPO2 CMS50QB TẠI CÔNG TY QUỐC TẾ VNS
✅ Luôn hỗ trợ tư vấn miễn phí cho khách hàng như;
✅ Hỗ trợ tham quan khảo sát thiết bị tận nơi cho khách hàng.
✅ Cung cấp giá cả hợp lý cho khách hàng khi mua sản phẩm của công ty.
✅ VNS Group là nhà phân phối chính thức của Contec Medical tại Việt Nam.
✅ Bảo hành 1 năm cho các sản phẩm Máy Đo Spo2 và Máy Tạo Oxy theo tiêu chuẩn nhà sản xuất
✅ Cung cấp những giải pháp tối ưu và tốt nhất cho khách hàng.
✅ Giải quyết nhanh chóng đơn đặt hàng khi có yêu cầu đặt hàng.
Quý khách có thể kham khảo một số sản phẩm khác của công ty TẠI ĐÂY